  ul listed file no. e43641 listed 367g complies with requirements of iec standards 947-4-1 and 947-5-1 low voltage directive iec = international electrotechnical commission ce testing and evaluation performed by the underwriters laboratories as a third party participant * * * manufactured under iso 9002 class 199 open style power relays class "b" coil insulation system 199 spdt 30 amp, 1-1/2 hp 199 dpdt 30 amp, 1-1/2 hp per pole 2 hp-2 pole switching 199 dpst-no 30 amps, 1-1/2 hp per pole 2 hp - 2 pole switching 199h dpdt 40 amps general purpose, 1-1/2 hp per pole; 2 hp - 2 pole switching 199 spst-no-dm 30 amps, 2 hp 199 spst-nc-db 30 amps, 2 hp 199db spst-no-dm with magnetic blowout for dc arc quenching 20 amps, 110 vdc 199de spst-no-dm with box terminals. 50 amps, 2 hp 199b dpdt with magnetic blowout for dc arc quenching 10 amps, 110 vdc spdt, dpdt, dpst-n.o., spst-n.c.-d.b. & spst-n.o.-d.m., 10 to 50 amps 3... 3 optional metal enclosure available, see page 12
120 vac 120 vac 12 vdc 24 vdc 12 vdc 24 vdc 290 290 70 290 70 290 w199ax-4 w199amx-4 w199x-2 w199x-3 w199mx-2 w199mx-3 general general specifica specifica tions tions spdt, 30 amps vertical mounting recommended with contacts up up 2.18 max. (55.37) 2.43 max. (61.7) 0.375 (9.5) 1.62 (41.14) 1.87 (47.5) 2.50 max. (63.5) 0.187 dia. (2 places) coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating: auxiliary switch: timing operate time: release time: 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 227 grams approx. 199 open style power relay class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c outline dimensions dimensions shown in inches & (millimeters). 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils-4 watts max. continuous silver cadmium oxide, gold flashed 5/16" diameter standard 30 amps up to 300 vac, 50/60hz 5 amps @ 480/600 vac, 50/60hz 0.75 pf inductive load. 1-1/2 hp motor load @ 120 thru 600 vac, 50/60 hz. 30 amps @ 28 vdc resistive load. 15 amps tungsten @ 120 vac nema a 600 pilot duty 50/60hz 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage wiring diagram (viewed from pin end) other coil voltages are available on special order. contact factory for special requirements. 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com auxiliary switch is installed on selected models shown in part number chart ac operated ac operated with spdt auxiliary switch dc operated dc operated with spdt auxiliary switch auxiliary switch optional metal enclosure available, see page 12 3... 4 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
general general specifica specifica tions tions coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating: auxiliary switch: timing operate time: release time: 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 311 grams approx. dpdt, 30 amps 12 290 1200 12 290 1200 18 70 290 6000 18 70 290 6000 w199ax-13 w199ax-14 w199ax-15 w199amx-63 w199amx-64 w199amx-65 w199x-11 w199x-12 w199x-13 w199x-14 w199mx-49 w199mx-50 w199mx-51 w199mx-52 24 vac 120 vac 240 vac 24 vac 120 vac 240 vac 6 vdc 12 vdc 24 vdc 110 vdc 6 vdc 12 vdc 24 vdc 110 vdc vertical mounting recommended with contacts up up 2.31 max. (58.67) 3.12 max. (79.2) 0.375 (9.5) 1.62 (41.14) 1.87 (47.5) 2.50 max. (63.5) 0.187 dia. (2 places) 199 open style power relay class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c ac operated dc operated outline dimensions dimensions shown in inches & (millimeters). 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils-4 matts max. continuous. silver cadmium oxide, gold flashed 5/16" diameter standard. 30 amps up to 300 vac, 50/60hz 5 amps @ 480/600 vac, 50/60hz 0.75 pf inductive load. 1-1/2 hp motor load each pole @ 120 thru 600 vac, 50/60 hz. 2 hp motor load @ 200 to 600 vac. when using two poles to switch both sides of load. 30 amps @ 28 vdc resistive load 15 amps tungsten @ 120 vac nema a 600 pilot duty 50/60hz 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage wiring diagram (viewed from pin end) ac operated with spdt auxiliary switch dc operated with spdt auxiliary switch 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com other coil voltages are available on special order. contact factory for special requirements. auxiliary switch auxiliary switch is installed on selected models shown in part number chart optional metal enclosure available, see page 12 3... 5 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
general general specifica specifica tions tions dpst-n.o., 30 amps vertical mounting recommended with contacts up up 2.25 max. (57.15) 2.43 max. (61.7) 1.62 (41.14) 0.187 dia. (2 places) 0.375 (9.5) 1.87 (47.5) 2.50 max. (63.5) 199 open style power relay 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 255 grams approx class outline dimensions dimensions shown in inches & (millimeters). 24 vac 120 vac 240 vac 24 vac 120 vac 240 vac 12 vdc 24 vdc 12 vdc 24 vdc 12 290 1200 12 290 1200 70 290 70 290 w199ax-8 w199ax-9 w199ax-10 w199amx-33 w199amx-34 w199amx-35 w199x-7 w199x-8 w199mx-26 w199mx-27 ac operated standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c dc operated ac operated with spdt auxiliary switch dc operated with spdt auxiliary switch coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating: auxiliary switch: timing operate time: release time: 85% of nominal voltage or less for ac coils, 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils 4 watts max continuous. silver cadmium oxide, gold flashed. 5/16" diameter standard 30 amps up to 300 vac, 50/60hz, 5 amps @ 480/600vac, 0.75 pf inductive load. 1-1/2 hp motor load (each pole) @120 thru 600 vac, 50/60 hz. 2 hp motor load @ 200 thru 600 vac, 50/60 hz only when using two poles to switch both sides of load. 30 amps @ 28 vdc resistive load each poles. 15 amps tungsten @ 120 vac. nema a600 pilot duty 50/60hz. 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com auxiliary switch is installed on selected models shown in part number chart auxiliary switch wiring diagram (viewed from pin end) other coil voltages are available on special order. contact factory for special requirements. optional metal enclosure available, see page 12 3... 6 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
general general specifica specifica tions tions vertical mounting recommended with contacts up up 2.25 max. (55.37) 2.43 max. (61.7) 1.62 (41.14) 0.187 dia. (2 places) coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating auxiliary switch: timing operate time: release time: 0.375 (9.5) 1.87 (47.5) 2.50 max. (63.5) spst n.c.- d.b. spst n.o.- d.m. 0.10 (2.54) 199 double make or break power relays 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 ccombination head screws molded phenolic, ul recognized (qmfz2) 227 grams approx. class outline dimensions dimensions shown in inches & (millimeters). 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils - 4 watts max continuous silver cadmium oxide, gold flashed. 5/16" diameter standard. 30 amps up to 300 vac, 50/60hz 5 amps @ 480/600 vac, 50/60hz 12 amps @ 480 vac, 10 amps @ 600 vac, 50/60hz 0.75 pf inductive load. 2 hp motor load @ 120 thru 600 vac, 50/60 hz. 30 amps @ 28 vdc resistive load. 15 amps tungsten @ 120 vac nema a600 pilot duty 50/60hz 10 amps @ 120/240 vac, 50/60 hz 1/4hp. 120/240 vac, 50/60 hz 1/2 amps @ 125 vdc, 1/4 amp @ 250 vdc 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage wiring diagram (viewed from pin end) double make 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com 120 vac 240 vac 120 vac 240 vac 12 vdc 12 vdc 24 vdc 12 vdc 12 vdc 24 vdc 290 1200 290 1200 70 70 290 70 70 290 w199adx-4 w199adx-5 w199admx-4 w199admx-5 w199dyx-2 w199dx-2 w199dx-3 w199dymx-2 w199dmx-2 w199dmx-3 spst-no-dm spst-no-dm spst-no-dm spst-no-dm spst-nc-db spst-no-dm spst-no-dm spst-nc-db spst-no-dm spst-no-dm contact configu- ration standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c ac operated dc operated ac operated with spdt auxiliary switch dc operated with spdt auxiliary switch auxiliary switch is installed on selected models shown in part number chart auxiliary switch other coil voltages are available on special order. contact factory for special requirements. double break double break double make auxiliary switch optional metal enclosure available, see page 12 spst-n.c.- d. b. or spst-n.o.- d.m., 30 amps 3... 7 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
120 vac 120 vac 24 vdc 48 vdc 24 vdc 48 vdc 290 290 290 1200 290 1200 w199adbx-4 w199adbmx-4 w199dbx-3 w199dbx-6 w199dbmx-3 w199dbmx-2 general general specifica specifica tions tions spst-n. o., 30 amps 20 amps @ 110 vdc vertical mounting recommended with contacts up up 2.18 max. (55.37) 2.43 max. (61.7) 1.62 (41.14) 0.187 dia. (2 places) coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating: dc rating: auxiliary switch: timing operate time: release time: dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight: ac operated 0.375 (9.5) 1.87 (47.5) 2.50 max. (63.5) 0.10 (2.54) magmetic blow out 199db dc switching power relay 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 227 grams approx. class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c outline dimensions dimensions shown in inches & (millimeters). 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com ac operated with spdt auxiliary switch dc operated dc operated with spdt auxiliary switch 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 10 va (60hz) ac @ 25 ? c dc coils-4 watts max. continuous. silver cadmium oxide, gold flashed. 5/16" diameter standard. 30 amps up to 300 vac, 50/60hz 12 amps @ 480 vac, 10 amps @ 600 vac, 50/60hz 0.75 pf inductive load. 1-1/2 hp motor load @ 120 thru 600 vac, 50/60 hz. 30 amps @ 28 vdc resistive load 15 amps tungsten @ 120 vac nema a600 pilot duty 50/60hz 20 amps @ 110 vdc, resistive; 8 amps @ 220 vdc resistive, 4 amps @ 325vdc resistive. 2 amps @ 500 vdc resistive. for inductive loads, contacts must be derated accordingly. capacitive loads must have current limiting to insure that inrush current will not exceed 100 amps. 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? auxiliary switch auxiliary switch is installed on selected models shown in part number chart wiring diagram (viewed from pin end) other coil voltages are available on special order. contact factory for special requirements. optional metal enclosure available, see page 12 3... 8
general general specifica specifica tions tions coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating: dc rating: auxiliary switch: 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage. 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 312 grams approx. dieltiming operate time: release time: ectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight: 290 290 290 6000 290 6000 w199abx-14 w199abmx-7 w199bx-13 w199bx-14 w199bmx-13 w199bmx-14 120 vac 120 vac 24 vdc 110 vdc 24 vdc 110 vdc ac operated vertical mounting recommended with contacts up up 2.53 max. (64.3) 3.12 max. (79.2) 0.375 (9.5) 1.62 (41.14) 1.87 (47.5) 2.50 max. (63.5) 0.187 dia. (2 places) magmetic blow out magmetic blow out ac operated with spdt auxiliary dpdt, 30 amps 10 amps @ 110 vdc 199b dc switching power relay class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c outline dimensions dimensions shown in inches & (millimeters). 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils - 4 watts max. continuous. silver cadmium oxide, gold flashed. 5/16" diameter standard. 30 amps up to 300vac, 50/60hz 5 amps @ 480/600 vac, 50/60hz 0.75 pf inductive load. 1-1/2 hp motor load (each pole) @ 120 thru 600 vac, 50/60 hz. 2 hp motor load @ 120 thru 600 vac, 50/60 hz only when using two poles to switch both sides of load. 30 amps @ 28 vdc resistive load. 15 amps tungsten @ 120 vac nema a 600 pilot duty 50/60hz 10 amps @110vdc, resistive; 4 amps @220vdc, resistive, 2 amps @ 325vdc resistive. for inductive loads, contacts must be derated accordingly. capacitive loads must have current limiting to insure that inrush current will not exceed 50 amps 10 amps 1/4 hp 125 or 250vac 1/2 amp 125 vdc 1/4 amp 250 vdc 3 amps 125 vac ?lamp? 10a 1/4hp 125 or 250vac 1/2a 125 vdc 1/4a 250vdc 3a 125vac "lamp" nc no com dc operated dc operated with spdt auxiliary auxiliary switch is installed on selected models shown in part number chart auxiliary switch wiring diagram (viewed from pin end) other coil voltages are available on special order. contact factory for special requirements. optional metal enclosure available, see page 12 3... 9
general general specifica specifica tions tions coil pull-in voltage: dropout voltage: coil resistance: ci\oil power: max. coil dissipation: duty: contacts contact material: contact rating: timing operate time: release time: 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils-4 watts max continuous silver cadmium oxide, gold flashed. 5/16" diameter standard 40 amps up to 300 vac, 50/60hz 5 amps @ 480/600 vac, 50/60hz 0.75 pf inductive load. 1-1/2 hp motor load esch pole @ 120 thru 600 vac, 50/60 hz. 2 hp motor load @ 200 to 600 vac when using two poles to switch both sides of load. 40 amps @ 28 vdc resistive load 15 amps tungsten @ 120 vac nema a600 pilot duty 50/60hz 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws 8-32 combination head screws molded phenolic, ul recognized (qmfz2) 311 grams approx. dpdt, 40 amps 12 290 1200 290 6000 w199ahx-13 w199ahx-14 w199ahx-15 w199hx-13 w199hx-14 24 vac 120 vac 240 vac,60 hz 24 vdc 110 vdc ac operated dc operated vertical mounting recommended with contacts up up 2.31 max. (58.67) 3.12 max. (79.2) 0.375 (9.5) 1.62 (41.14) 1.87 (47.5) 2.50 max. (63.5) 0.187 dia. (2 places) 199h high power relay class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c outline dimensions dimensions shown in inches & (millimeters). auxiliary contacts and other coil voltages are available on special order. contact factory for special requirements. wiring diagram (viewed from pin end) optional metal enclosure available, see page 12 3... 10 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
120 vac 24 vdc 290 290 w199adex-4 w199dex-3 general general specifica specifica tions tions spst-n.o.- d.m., 50 amps vertical mounting recommended with contacts up up 0.187 dia. (2 places) coil pull-in voltage: dropout voltage: coil resistance: coil power: max. coil dissipation: duty: contacts contact material: contact rating timing operate time: release time: 85% of nominal voltage or less for ac coils 80% of nominal voltage or less for dc coils 10% of nominal voltage or more @ 25 ? c 10% @ 25 ? c 2.0 watts dc., 10 va (60hz) ac @ 25 ? c dc coils-4 watts max. continuous. silver cadmium oxide, gold flashed. 5/16" diameter standard. 50 amps up to 300vac, 50/60hz 50 amps @ 28 vdc resistive load, loads must have current limiting to insure that inrush current will not exceed 100 amps nema a600 pilot duty 50/60hz 40 milliseconds max. @ nominal voltage 30 milliseconds max. @ nominal voltage. 1500 v rms 2200 v rms (ac) -30 ? c to +50 ? c, (dc) -30 ? c +60 ? c -55 ? c to +100 ? c 100,000 operations @ rated resistive load 1,000,000 operations @ no load 6-32 combination head screws amg 2-12 pressure wire connector molded phenolic, ul recognized (qmfz2) 227 grams approx. auxiliary contacts and other coil voltages are available on special order. contact factory for special requirements. ac operated with screw terminals dc operated with screw terminals 3.50 max. (88.9) 199de high power relay 2.18 max. (55.37) 2.43 max. (61.7) 1.62 (41.14) 0.375 (9.5) 1.87 (47.5) 2.50 max. (63.5) 0.10 (2.54) box terminal?s 50 amp box terminals accept no.14 thru no. 6 awg. wire wiring diagram (viewed from pin end) class standard part numbers nominal input voltage nominal resistance (ohms) coil measured @ 25?c outline dimensions dimensions shown in inches & (millimeters). optional metal enclosure available, see page 12 3... 11 dielectric strength between open contacts: mutually insulated conductive elements: temperature operating range: non-operating storage range: life expectancy electrical: mechanical: miscellaneous coil terminals: load terminals: base material: weight:
50-1289-1 14 holes tapped # 8 - 32 1.875 (47.63) 2.500 (63.50) 1.12 (28.4) 4.125 (104.77) 5.220 (132.58) 3 mtg. holes 0.218 dia. (5.537) 3.01 (76.58) 3.38 (85.85) 0.96 typ. (24.4) 0.060 (1.52) 1.50 (38.1) 0.88 knock-out holes 2 knock-out holes each end universal mount metal enclosure 50 standard part number description outline dimensions dimensions shown in inches & (millimeters). metal enclosure 1.62 (41.2) 2.00 (50.8) cover & relay mounting screws included 3... 12


▲Up To Search▲   

 
Price & Availability of 199HDPDT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X